Solar Calculator Canada

Solar Power Calculator for Bolton Centre, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Bolton Centre
  • GPS Coordinates: 45.2, -72.35
  • Elevation: 269 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Bolton Centre: 38o
  • Average yearly irradiance: 1443.59 kWh/m2
  • Average yearly power output: 121184 kWh
Sun Path Bolton Centre

Average yearly irradiance delivered by the Sun in Bolton Centre is 1443.59/kWh/m2 at the optimal panel slope of 38o. After taking all losses into account, you can expect about 121184 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 38o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.62 81.2
February 3.21 90.01
March 4.15 128.67
April 4.65 139.46
May 5.14 159.49
June 5.14 154.25
July 5.41 167.78
August 5.2 161.29
September 4.45 133.55
October 3.2 99.15
November 2.5 75
December 1.73 53.74
Total yearly 1443.59

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 245.2 7601.29
February 297.56 8331.78
March 368.92 11436.5
April 393.59 11807.7
May 420.39 13032.2
June 410.79 12323.7
July 428.11 13271.4
August 414.85 12860.2
September 360.04 10801.1
October 268.93 8336.7
November 217.61 6528.24
December 156.54 4852.7
Total yearly 121184

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Bolton Centre solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 178.93 5546.68
February 241.04 6749.01
March 330.71 10252
April 388.54 11656.2
May 442.07 13704.2
June 444.65 13339.6
July 458.39 14210.2
August 420.2 13026.1
September 335.39 10061.8
October 227.07 7039.24
November 165 4949.87
December 112.86 3498.66
Total yearly 114033

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 196.5 6091.51
February 256.71 7187.96
March 342.85 10628.3
April 393.31 11799.4
May 441.11 13674.5
June 441.01 13230.2
July 455.68 14126.2
August 422.85 13108.3
September 344.44 10333.3
October 239.08 7411.46
November 179.12 5373.59
December 124.41 3856.7
Total yearly 116821

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 212.38 6583.92
February 270.55 7575.53
March 352.89 10939.5
April 396 11880.1
May 437.9 13574.8
June 435.06 13051.7
July 450.69 13971.3
August 423.35 13124
September 351.48 10544.5
October 249.5 7734.65
November 191.79 5753.76
December 134.86 4180.74
Total yearly 118915

Bolton Centre Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 226.54 7022.81
February 282.53 7910.83
March 360.8 11184.8
April 396.63 11898.8
May 432.57 13409.7
June 427.07 12812.1
July 443.54 13749.8
August 421.73 13073.6
September 356.5 10695.1
October 258.32 8007.81
November 202.99 6089.7
December 144.2 4470.08
Total yearly 120325

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.91% angle of incidence loss and -3.93% temperature and irradiance loss. This totals to about -16.05%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

MagpieCheveryVieux-FortSalmon BayRivi�re-Saint-PaulKeyanoWestportHebbvilleTivertonDundeePort WilliamsSheffordValcourtWestburyRoxtonSaint-CamilleSussex CornerStratfordHam-NordChichesterArundelTide HeadSaint-GodefroiLaunayTr�cessonMurdochville